Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Two-Implant-Supported Single Molar Replacement: Interdental Space Requirements and Comparison to Alternative Options
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 17 , Issue 5
September/October 1997

Pages 427-435


Two-Implant-Supported Single Molar Replacement: Interdental Space Requirements and Comparison to Alternative Options

Balshi/Wolfinger


PMID: 9497731
DOI: 10.11607/prd.00.0229

Posterior single-tooth implant resotrations are subjected to an increased risk of bending overload. A high incidence of implant fracture has been reported when using a single standard 3.75-mm-diameter implant to support a molar restoration. The purpose of this article is to demonstrate the clinical feasibility of placing two implants to support a molar restoration and to compare this treatment option to the use of a single standard implant or a wide-diameter implant. Two osseointegrated dental implants used to support a molar restoration in interdental spaces as small as 10 mm is shown to be effective and predictable in 60 restorations over the past 7 years. The use of two implants provides more surface area for osseointegration and spreads the occlusal loading forces out over a wider area, reducing the potential bending forces that would otherwise exist in a single-implant molar restoration.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help